Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 271
Filtrar
1.
Dentomaxillofac Radiol ; 53(2): 153-160, 2024 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-38224272

RESUMO

OBJECTIVES: To evaluate the effect of the presence and the number of high-density objects in the exomass on the volume of a high-density object in cone-beam CT (CBCT). METHODS: Cylinders of cobalt-chromium (Co-Cr), titanium (Ti), and zirconium (Zi) were inserted into a polymethylmethacrylate phantom in five different combinations of number and position: 1-no cylinder; 2-one cylinder in a posterior region; 3-one cylinder in an anterior region; 4-two cylinders in posterior regions; and 5-three cylinders in anterior and posterior regions. The phantom underwent CBCT scanning using OP300 and X800 systems, with the afore mentioned cylinders of the same composition placed in the exomass and an additional high-density cylinder placed in the centre of the field of view (FOV), corresponding to the left-anterior region. The tomographic volume of the cylinder inside the FOV was measured using semi-automatic segmentation. The volumetric alteration (VA) between the segmented and physical volumes, in percentage, was compared among the experimental groups using repeated measures ANOVA and Tukey post-hoc (α = 5%). RESULTS: The factors material, combination, and their interaction affected the volume or both CBCT systems. In OP300, more cylinders in the exomass reduced the VA, mainly for Co-Cr. In X800, more cylinders in the exomass tended to increase the VA inside the FOV, except for Zi. CONCLUSIONS: In general, the presence of high-density objects in the exomass influences the VA of the object inside the FOV, although this oscillates according to object composition, number and position in the exomass, and CBCT system.


Assuntos
Artefatos , Tomografia Computadorizada de Feixe Cônico , Humanos , Imagens de Fantasmas
2.
Artigo em Inglês | MEDLINE | ID: mdl-37980244

RESUMO

OBJECTIVE: We investigated the influence of voxel and field of view (FOV) sizes on expression of the volumetric alteration artifact (VAA) of 5 high-density materials in 2 cone beam computed tomography (CBCT) devices. STUDY DESIGN: Cylinders of amalgam, cobalt-chromium, gutta-percha, titanium, and zirconium were individually positioned in a polymethyl methacrylate phantom. OP300 Maxio and ProMax 3D Classic CBCT devices were used to acquire images with varying voxel and FOV sizes, totaling 585 scans. Two evaluators segmented the high-density cylinder images to obtain the tomographic volumes. The difference between the tomographic and physical volume of each cylinder (i.e., volumetric alteration) was calculated. Statistical analysis was conducted with multiway ANOVA and the Tukey post hoc test (α = 5%). Evaluator reliability was measured with the intraclass correlation coefficient (ICC). RESULTS: All studied parameters and nearly all interactions influenced the VAA (P < .05). The post hoc test demonstrated less volumetric alteration for the smallest voxel sizes, 61 × 78 mm FOV, and gutta-percha for OP300, and for the smallest voxel sizes, 80 × 80 mm FOV, and gutta-percha and titanium for ProMax 3D (P < .05). The ICC demonstrated perfect reliability (1.00). CONCLUSIONS: Voxel and FOV sizes influenced VAA expression. Using smaller voxel sizes, the 61 × 78 mm FOV for OP300 and the 80 × 80 mm FOV for ProMax 3D, and materials with lower density and lower atomic number reduced VAA expression.


Assuntos
Artefatos , Guta-Percha , Humanos , Reprodutibilidade dos Testes , Titânio , Tomografia Computadorizada de Feixe Cônico
3.
Braz Dent J ; 34(4): 150-157, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37909638

RESUMO

This study aimed to assess the influence of the file format on the image quality parameters (image noise, brightness, and uniformity) of periapical radiographs acquired with different digital systems. Radiographic images of an acrylic phantom were acquired with two digital systems - Digora Toto and Express, and exported into five different file formats - TIFF, BMP, DICOM, PNG, and JPEG. Image noise, image brightness (mean of gray values), and image uniformity (standard deviation of gray values) were evaluated in all images. A two-way analysis of variance with Tukey's test as a post-hoc test was used to compare the results, considering the file formats and radiographic systems as the studied factors. A significance level of 5% was adopted for all analyses. The DICOM image file format presented lower image noise, higher brightness (higher mean gray values), and greater image uniformity (p<0.001) than the other file formats, which did not differ from each other for both digital radiography systems (p>0.05). The Express system revealed lower image noise and greater image uniformity than the Digora Toto system regardless of the image file format (p<0.001). Moreover, the Express showed higher brightness than the Digora Toto for all image file formats (p<0.001), except for the DICOM image file format, which did not significantly differ between the digital radiography systems tested (p>0.05). The DICOM image file format showed lower image noise, higher brightness, and greater image uniformity than the other file formats (TIFF, BMP, PNG, and JPEG) in both digital radiography systems tested.


Assuntos
Radiografia Dentária Digital , Radiografia Dentária Digital/métodos
4.
Clin Oral Investig ; 27(12): 7881-7888, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37993703

RESUMO

OBJECTIVE: To compare the dosimetry between convex triangular fields of view (FOV) and similar dimension cylindrical FOVs of two cone-beam computed tomography (CBCT) models. METHODS: Optically stimulated luminescence dosimeters (OSLDs) were placed in fiducial anatomical locations in an anthropomorphic phantom representing an adult head male for dosimetry scans. Convex triangular FOVs (100 × 80 mm/maxilla-mandible; 100 × 50 mm mandible; 100 × 50 mm/maxilla) from Veraviewepocs 3D R100 (J. Morita, Kyoto, Japan) (R100) and Veraview® X800 (J. Morita, Kyoto, Japan) (X800) and cylindrical FOVs from R100 and X800 (80 × 80 mm/maxilla-mandible; 80 × 50 mm/mandible; 80 × 50 mm/maxilla) were obtained, resulting in 12 different scan protocols. Equivalent doses for each relevant organ/tissue and the effective dose for each protocol were calculated. Mean effective doses were compared by the two-way analysis of variance (ANOVA) with Tukey's post hoc test to evaluate the effect of the FOV and device (α = 0.05). RESULTS: The effective doses ranged between 69 and 324 µSv for the convex triangular FOVs and 76 and 332 µSv for the cylindrical FOVs. Convex triangular FOVs from the R100 device had effective doses 2.3 to 15.3% lower than their corresponding cylindrical FOVs with similar height (p < 0.05), and that difference ranged between 8.8 and 11.8% for the X800 device (p < 0.05). CONCLUSION: Convex triangular fields of view delivered slightly lower effective doses than the cylindrical fields of view of similar dimensions in the R100 and X800 CBCT devices. CLINICAL RELEVANCE: Understanding the influence of the image geometry formation in effective dose allows optimization to reduce patient dose.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Radiometria , Adulto , Masculino , Humanos , Doses de Radiação , Tomografia Computadorizada de Feixe Cônico/métodos , Mandíbula/diagnóstico por imagem , Maxila , Imagens de Fantasmas
5.
Braz. dent. j ; 34(4): 150-157, July-Aug. 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1520332

RESUMO

Abstract This study aimed to assess the influence of the file format on the image quality parameters (image noise, brightness, and uniformity) of periapical radiographs acquired with different digital systems. Radiographic images of an acrylic phantom were acquired with two digital systems - Digora Toto and Express, and exported into five different file formats - TIFF, BMP, DICOM, PNG, and JPEG. Image noise, image brightness (mean of gray values), and image uniformity (standard deviation of gray values) were evaluated in all images. A two-way analysis of variance with Tukey's test as a post-hoc test was used to compare the results, considering the file formats and radiographic systems as the studied factors. A significance level of 5% was adopted for all analyses. The DICOM image file format presented lower image noise, higher brightness (higher mean gray values), and greater image uniformity (p<0.001) than the other file formats, which did not differ from each other for both digital radiography systems (p>0.05). The Express system revealed lower image noise and greater image uniformity than the Digora Toto system regardless of the image file format (p<0.001). Moreover, the Express showed higher brightness than the Digora Toto for all image file formats (p<0.001), except for the DICOM image file format, which did not significantly differ between the digital radiography systems tested (p>0.05). The DICOM image file format showed lower image noise, higher brightness, and greater image uniformity than the other file formats (TIFF, BMP, PNG, and JPEG) in both digital radiography systems tested.


Resumo Este estudo teve como objetivo avaliar a influência do formato do arquivo nos parâmetros de qualidade de imagem (ruído de imagem, brilho e uniformidade) de radiografias periapicais adquiridas com diferentes sistemas digitais. As imagens radiográficas de um fantoma de acrílico foram adquiridas com dois sistemas digitais - Digora Toto e Express, e exportadas em cinco formatos de arquivo diferentes - TIFF, BMP, DICOM, PNG e JPEG. O ruído da imagem, o brilho da imagem (média dos valores de cinza) e a uniformidade da imagem (desvio padrão dos valores de cinza) foram avaliados em todas as imagens. A análise de variância (ANOVA) bidirecional com o teste post-hoc de Tukey foi aplicada para comparar os resultados, considerando os formatos de arquivo e os sistemas radiográficos como os fatores estudados. Um nível de significância de 5% foi adotado para todas as análises. O formato de arquivo de imagem DICOM apresentou menor ruído de imagem, maior brilho (maiores valores médios de cinza) e maior uniformidade de imagem (p<0,001) do que os outros formatos de arquivo, que não diferiram entre si para ambos os sistemas de radiografia digital (p>0,05). O sistema Express apresentou menor ruído de imagem e maior uniformidade de imagem que o sistema Digora Toto, independentemente do formato do arquivo de imagem (p<0,001). Além disso, o Express mostrou maior brilho do que o Digora Toto para todos os formatos de arquivo de imagem (p<0,001), exceto para o formato de arquivo de imagem DICOM, que não diferiu significativamente entre os sistemas de radiografia digital testados (p>0,05). O formato de arquivo de imagem DICOM mostrou menor ruído de imagem, maior brilho e maior uniformidade de imagem do que os outros formatos de arquivo (TIFF, BMP, PNG e JPEG) em ambos os sistemas de radiografia digital testados.

7.
Dentomaxillofac Radiol ; 52(7): 20230147, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37493606

RESUMO

OBJECTIVE: To compare cylindrical and convex triangular field-of-views (FOVs) concerning the magnitude of artefacts from high-density materials in cone-beam CT (CBCT). METHODS AND MATERIALS: Cylinders of amalgam, chromium-cobalt, titanium, and zirconia were individually placed in the anterior and posterior regions of a polymethylmethacrylate phantom and scanned using cylindrical and convex triangular FOVs of the Veraview X800 CBCT device. Using the Image J software, 15 square regions of interest (ROIs) were placed in the axial reconstruction around the middle level of the cylinder and at distances of 0.5, 1.0, and 1.5 cm from the centre of the cylinder. Mean grey value and standard deviation of each ROI were averaged for each distance and subtracted from the values of a control ROI to calculate the magnitude of the artefacts by the grey value mean difference (GVMD) and grey value standard deviation (GVSD). Multiway analysis of variance with Tukey post-hoc test with a significance level of 5% evaluated the effect of the shape of the FOV, position inside the FOV, high-density material, and the distance of the artefact from the material. RESULTS: The convex triangular FOV increased the GVSD for all materials in the anterior and posterior regions at 0.5 cm compared to the cylindrical FOV (p < 0.0001). The convex triangular FOV showed greater GVMD for chromium-cobalt and zirconium in the anterior region and all materials in the posterior region at all distances (p < 0.0001). CONCLUSION: The FOV shape influences the magnitude of artefacts from high-density materials. The convex triangular FOV showed greater artefact magnitude with variability among the high-density materials, region in the FOV, and distance from the material.


Assuntos
Artefatos , Tomografia Computadorizada de Feixe Cônico , Humanos , Cobalto , Cromo , Imagens de Fantasmas
8.
Dentomaxillofac Radiol ; 52(7): 20230174, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37493608

RESUMO

OBJECTIVES: To subjectively assess radiographs obtained with photostimulable phosphor (PSP) plates exposed to clinical levels of ambient light prior to read-out to potentially set a safe limit for acceptable image quality. METHODS AND MATERIALS: Six dental regions of a dry human skull were X-rayed using PSP plates from VistaScan and Express under four exposure times: 0.1, 0.2, 0.32, and 0.4 s. Before read-out, the PSP plates were exposed to ambient light for 0, 5, 10, 30, 60, and 90 s. Six observers were asked to classify the 288 resulting radiographs as acceptable or unacceptable based on the identification of anatomical structures and global image quality. The number of answers classifying radiographs as unacceptable was used to calculate a rejection rate; a pairwise comparison for better image quality was further conducted among radiographs considered acceptable. Reproducibility was tested by having 25% of all experimental groups reassessed. RESULTS: Intra- and interobserver agreement ranged from 0.87 to 1.00 and from 0.81 to 0.92, respectively. Exposure of PSP plates to ambient light increased rejection rates mostly as of 10 s. In the pairwise comparison, subtle differences were observed between radiographs obtained with PSP plates not exposed and those exposed to ambient light for 5 s. CONCLUSIONS: Ambient light exposure of PSP plates impairs the image quality of radiographs. A safe limit of ambient light exposure of 5 s for VistaScan and Express should be considered. Ambient light exposure of PSP plates within safe limits can avoid retakes and reduce unnecessary patient exposure to X-rays.


Assuntos
Intensificação de Imagem Radiográfica , Radiografia Dentária Digital , Humanos , Radiografia Dentária Digital/métodos , Reprodutibilidade dos Testes , Intensificação de Imagem Radiográfica/métodos , Raios X , Crânio
9.
Dentomaxillofac Radiol ; 52(8): 20230029, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37427699

RESUMO

OBJECTIVES: To assess the distortion of high-density materials using two CBCT devices presenting convex triangular and cylindrical fields of view (FOVs). METHODS AND MATERIALS: Four high-density cylinders were individually placed in a polymethylmethacrylate phantom. 192 CBCT scans were acquired using the convex triangular and cylindrical FOVs of Veraviewepocs® R100 (R100) and Veraview® X800 (X800) devices. Using HorosTM's software, two oral radiologists determined the cylinders' horizontal and vertical dimensional alterations. Nine oral radiologists subjectively identified each cylinder's axial shape distortion. Statistical analysis comprised Multiway ANOVA (α = 5%), and the Kruskal-Wallis test. RESULTS: The distortion in the axial plane was greater in the convex triangular FOVs for both devices in almost all the materials (p < 0.05). The evaluators subjectively identified a shape distortion in both FOVs for R100 device (p < 0.001), while no distortion was identified for X800 device (p = 0.620). A vertical magnification of all materials was observed in both FOVs for both devices (p < 0.05). No differences among vertical regions (p = 0.988) nor FOVs (p = 0.544) were found for the R100 device, while all materials showed higher magnification in all regions in the cylindrical FOV (p < 0.001) of the X800 device. CONCLUSIONS: The convex triangular FOV influenced the axial distortion of the high-density materials in both devices. A vertical magnification was observed in both FOVs of both devices, but it was greater in the cylindrical FOV of the X800 device.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Humanos , Tomografia Computadorizada de Feixe Cônico/métodos , Imagens de Fantasmas
10.
BMC Oral Health ; 23(1): 361, 2023 06 04.
Artigo em Inglês | MEDLINE | ID: mdl-37271800

RESUMO

BACKGROUND: Since the muscles of chewing are involved in the region of the mandibular angle, important structures in surgical and orthodontic procedures, to study its morphological aspects and the possible influence of different patterns of skeletal development would be of interest. Thus, this study aimed to assess the influence of patient characteristics - such as sex, skeletal malocclusion (Class I, Class II, and Class III) and facial type (brachycephalic, mesocephalic, and dolichocephalic) - on the width, height, thickness, and volume of the mandibular angle, using cone-beam computed tomography (CBCT) scans. METHODS: CBCT scans were assessed - 144 men and 154 women, total of 298 - and classified according to skeletal patterns (skeletal malocclusions and facial types). Width, height, and thickness of the mandibular angle were measured using OnDemand 3D software. The volumetric measures of the mandibular angle were obtained using the ITK-SNAP software. Analysis of Variance (multiway ANOVA) with Tukey's post-hoc test compared the data, with a 5% significance level. RESULTS: Among the factors studied, sex significantly influenced all the analyzed variables (height, width, thickness, and volume of the mandibular angle) (p < 0.05); in general, male individuals presented higher values than females. In some cases, the skeletal malocclusion and facial type factors influenced only the width and height variables (p < 0.05); in general, the Class III and dolichocephalic individuals presented higher values in relation to the other types of skeletal malocclusions and facial types. CONCLUSIONS: Variations in the craniofacial growth pattern, considering the different skeletal malocclusions and facial types, had some influence in the width and height dimensions of the mandibular angle. Furthermore, sex influenced all the studied variables.


Assuntos
Má Oclusão Classe III de Angle , Má Oclusão , Humanos , Masculino , Feminino , Estudos Retrospectivos , Mandíbula/diagnóstico por imagem , Má Oclusão/diagnóstico por imagem , Face/diagnóstico por imagem , Face/anatomia & histologia , Tomografia Computadorizada de Feixe Cônico/métodos , Má Oclusão Classe III de Angle/diagnóstico por imagem , Cefalometria/métodos
11.
Dentomaxillofac Radiol ; 52(4): 20220370, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36988093

RESUMO

OBJECTIVE: To assess the subjective image quality of original and manually enhanced radiographs acquired at different X-ray exposure times and using different digital systems. METHODS: A total of 500 radiographs obtained under 10 exposure times, 5 digital systems, and 2 enhancement conditions were assessed by 5 observers, who were asked to categorize each radiograph into acceptable or unacceptable. A radiograph was considered to be acceptable when at least four out of five observers found it acceptable. Descriptive analysis was used to summarize the outcomes and compare the subjective image quality of original and manually enhanced digital radiographs among different X-ray exposure times and digital systems. RESULTS: Express had six exposure times producing acceptable original images within a range from 0.063 to 0.4 s, followed by Digora Toto, which had five within a range from 0.063 to 0.32 s, Digora Optime, which had four within a range from 0.063 to 0.2 s,and SnapShot and VistaScan, which had 2 (0.2 and 0.32 s) and 1 (0.63 s), respectively. Image enhancement turned unacceptable images into acceptable ones in four digital systems: SnapShot at three exposure times, Digora Toto at two exposure times, Express at one exposure time, and VistaScan at four exposure times. CONCLUSION: Image enhancement based on brightness and/or contrast adjustments may be necessary to reveal the useful dynamic range of some digital radiographic systems and PSP-based systems may not necessarily have a wider range than sensor-based systems.


Assuntos
Intensificação de Imagem Radiográfica , Radiografia Dentária Digital , Humanos , Radiografia Dentária Digital/métodos , Intensificação de Imagem Radiográfica/métodos
12.
Braz Dent J ; 34(1): 39-44, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36888843

RESUMO

The study aimed to assess the influence of excessive use of a photostimulable phosphor plate (PSP) on the density, image noise, and contrast of radiographs. For that, radiographs of an acrylic block were acquired with a PSP of the Express intraoral system to assess the density and image noise. Initially, five images were obtained and exported (first group). After 400 exposures to X-rays and scannings of PSP, other five images were obtained and exported (second group). The same procedure was done after 800 (third group), 1200 (fourth group), 1600 (fifth group), and 2000 acquisitions (sixth group), resulting in 30 images to be evaluated. The mean and standard deviation of the gray values were calculated for the images using the ImageJ software. For contrast analysis, radiographs of an aluminum step-wedge were acquired with a new PSP following the same acquisition intervals. The percentage of contrast variation was calculated. Another two unused PSP receptors were employed to evaluate the method's reproducibility. The comparison of the results among the acquisition groups was performed with one-way Analysis of Variance (α=0.05). Intraclass Correlation Coefficient (ICC) assessed the reproducibility of the receptors. Image noise did not differ among the groups (p>0.05). There was a slight increase in density after 400 acquisitions and a slight difference in contrast for all acquisition groups without a pattern of increase or decrease (p<0.05). ICC showed excellent reliability for the methods. Therefore, excessive PSP use slightly affected the radiograph's density and contrast.


Assuntos
Radiografia Dentária Digital , Radiografia Dentária Digital/métodos , Reprodutibilidade dos Testes
13.
Dentomaxillofac Radiol ; 52(3): 20220213, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36802857

RESUMO

OBJECTIVE: To present patient dose levels for different CBCT scanners, acquired by a dose monitoring tool in a University Hospital, as a function of field of view (FOV), operation mode, and patient age. METHODS: An integrated dose monitoring tool was used to collect radiation exposure data [type of CBCT unit, dose-area product (DAP), FOV size, and operation mode] and patient demographic information (age, referral department) performed on a 3D Accuitomo 170 and a Newtom VGI EVO unit. Effective dose conversion factors were calculated and implemented into the dose monitoring system. For each CBCT unit, the frequency of examinations, clinical indications, and effective dose levels were obtained for different age and FOV groups, and operation modes. RESULTS: A total of 5163 CBCT examinations were analyzed. Surgical planning and follow-up were the most frequent clinical indications. For the standard operation mode, effective doses ranged from 35.1 to 300 µSv and 9.26-117 µSv using 3D Accuitomo 170 and Newtom VGI EVO, respectively. In general, effective doses decreased with increasing age and FOV size reduction. CONCLUSIONS: Effective dose levels varied notably between systems and operation modes.Operation mode selection and FOV size were indication-oriented, with larger FOV sizes election serving surgical planning and follow-up. Seeing the influence of FOV size on effective dose levels, manufacturers could be advised to move toward patient-specific collimation and dynamic FOV selection. Systematically monitoring patient doses could be recommended for steering future CBCT optimization.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Radiografia Dentária , Humanos , Imagens de Fantasmas , Doses de Radiação , Hospitais
14.
Braz. dent. j ; 34(1): 39-44, Jan.-Feb. 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1420574

RESUMO

Abstract The study aimed to assess the influence of excessive use of a photostimulable phosphor plate (PSP) on the density, image noise, and contrast of radiographs. For that, radiographs of an acrylic block were acquired with a PSP of the Express intraoral system to assess the density and image noise. Initially, five images were obtained and exported (first group). After 400 exposures to X-rays and scannings of PSP, other five images were obtained and exported (second group). The same procedure was done after 800 (third group), 1200 (fourth group), 1600 (fifth group), and 2000 acquisitions (sixth group), resulting in 30 images to be evaluated. The mean and standard deviation of the gray values were calculated for the images using the ImageJ software. For contrast analysis, radiographs of an aluminum step-wedge were acquired with a new PSP following the same acquisition intervals. The percentage of contrast variation was calculated. Another two unused PSP receptors were employed to evaluate the method's reproducibility. The comparison of the results among the acquisition groups was performed with one-way Analysis of Variance (α=0.05). Intraclass Correlation Coefficient (ICC) assessed the reproducibility of the receptors. Image noise did not differ among the groups (p>0.05). There was a slight increase in density after 400 acquisitions and a slight difference in contrast for all acquisition groups without a pattern of increase or decrease (p<0.05). ICC showed excellent reliability for the methods. Therefore, excessive PSP use slightly affected the radiograph's density and contrast.


Resumo Objetivou-se avaliar a influência do uso excessivo de uma placa de fósforo fotoestimulável (PSP) na densidade, ruído e contraste das radiografias. Foram adquiridas radiografias de um bloco de acrílico com uma PSP do sistema intraoral Express para avaliar a densidade e o ruído da imagem. Inicialmente, cinco imagens foram obtidas e exportadas (primeiro grupo). Após 400 exposições aos raios X e escaneamentos, outras cinco imagens foram obtidas e exportadas (segundo grupo). O mesmo procedimento foi feito após 800 (terceiro grupo), 1200 (quarto grupo), 1600 (quinto grupo) e 2000 aquisições (sexto grupo), resultando em 30 imagens a serem avaliadas. A média e o desvio padrão dos valores de cinza foram calculados para as imagens usando o software ImageJ. Para análise de contraste, foram adquiridas radiografias de uma escala de alumínio com uma nova PSP seguindo os mesmos intervalos de aquisição. A porcentagem de variação do contraste foi calculada. Outras duas PSP sem uso prévio foram utilizadas para avaliar a reprodutibilidade dos métodos. A comparação dos resultados entre os grupos de aquisição foi realizada pela Análise de Variância one-way (α=0,05). O Coeficiente de Correlação Intraclasse (ICC) avaliou a reprodutibilidade dos receptores. O ruído da imagem não diferiu entre os grupos (p>0,05). Houve um leve aumento na densidade após 400 aquisições e uma pequena diferença no contraste para todos os grupos de aquisição sem padrão de aumento ou diminuição (p<0,05). O ICC mostrou excelente confiabilidade para os métodos. Portanto, o uso excessivo da PSP afetou levemente a densidade e o contraste radiográfico.

15.
Artigo em Inglês | MEDLINE | ID: mdl-36566136

RESUMO

OBJECTIVE: The aim of this study was to evaluate the influence of the extensive use of a photostimulable phosphor (PSP) receptor on the diagnosis of proximal carious lesions. STUDY DESIGN: Forty posterior teeth were paired and mounted in 20 phantoms. Using a PSP receptor of the Express intraoral system, 1 radiograph of each phantom was acquired, totaling 20 radiographs (group 1). After 400 acquisitions, another radiograph of each phantom was obtained, totaling 20 new radiographs (group 2). This procedure was also done after 800 (group 3), 1,200 (group 4), and 1,600 (group 5) acquisitions, resulting in 100 radiographs. Another 40 radiographs (20 phantoms × 2 groups) were obtained with a second PSP sensor to evaluate the diagnostic replicability of the receptors. All 140 radiographs were assessed independently by 5 examiners for the presence of proximal caries. Area under the receiver operating characteristic curve, sensitivity, and specificity were calculated and compared among the groups by analysis of variance. The Student t test evaluated the diagnostic replicability of the receptors. The significance level was set at 5% (P < .05). RESULTS: The diagnostic outcomes for proximal caries did not differ among the groups (P ≥ .37). The diagnostic values did not differ among the radiographs acquired with the 2 PSP receptors (P ≥ .75). CONCLUSIONS: The diagnosis of proximal carious lesions was not affected by extensive use of the PSP receptor.


Assuntos
Cárie Dentária , Radiografia Interproximal , Humanos , Cárie Dentária/diagnóstico por imagem , Dente Molar/diagnóstico por imagem , Dente Molar/patologia , Sensibilidade e Especificidade
16.
Braz Oral Res ; 36: e130, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36383836

RESUMO

This study aimed to assess the microstructure, chemical composition, and image quality of different photostimulable phosphor plates (PSP). Four PSP systems, Express®, Digora®, VistaScan®, and Apixia,® were assessed. Five radiographs of a homogeneous acrylic phantom were obtained with the PSP of each system, to acquire a total of 20 images. The images were objectively evaluated for uniformity using mean grey and standard deviation (SD) of their grey values. PSP receptors were analyzed using scanning electron microscopy (SEM) to determine the thickness of the granule layer and the size of the granules. The chemical composition of the PSP receptors was analyzed using total reflection X-ray fluorescence (TXRF). VistaScan showed more uniform and higher density images than the other tested systems (p < 0.05), as well as the lowest SD of grey values (p < 0.05). Regarding the microstructure of the receptors, Digora and VistaScan had thicker granule layers than Express and Apixia, and VistaScan had smaller granules than Digora and Express (p < 0.05). Fourteen chemical elements were detected in the receptors, with barium being the element with the highest concentration in all PSP systems. The microstructure, chemical composition, and image quality varied among all four PSP receptors studied. VistaScan receptors showed the smallest variation in granule size, one of the thickest granule layers, and the most uniform and least noisy images.


Assuntos
Intensificação de Imagem Radiográfica , Radiografia Dentária Digital , Radiografia Dentária Digital/métodos , Imagens de Fantasmas , Intensificação de Imagem Radiográfica/métodos
17.
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1405315

RESUMO

ABSTRACT: Generally, primary methods of identification as the fingerprint analysis, dental analysis or DNA examination are indicated for the establishment of the identity of a corpse. In situations with poor body conservation, such as in advanced stage of putrefaction or skeletonization, imaging exams like medical and dental computed tomography can assist in the process of identification. The frontal sinuses present anatomical characteristics that allow the establishment of the identity of an in dividual. In this case report we used the technique of three-dimensional construction of the frontal sinuses through the generation of solid figures representative of the sinus morphology. After the comparative analysis of the antemortem and postmortem tomography of the alleged victim, we could establish similarities in both the variations in size, shape, symmetry and contour of borders, and the presence and number of septa, allowing us to infer that the two images described belong to the same individual, thus establishing the identity of the corpse found.


RESUMEN: Generalmente, los métodos primarios de identificación como el análisis dactiloscópico, el análisis dental o el examen de ADN están indicados para el establecimiento de la identidad de un cadáver. En situaciones de mala conservación del cuerpo, como en etapa avanzada de putrefacción o esqueletización, los exámenes de imagen como la tomografía computarizada médica y dental pueden ayudar en el proceso de identificación. Los senos frontales presentan características anatómicas que permiten establecer la identidad de un individuo. En este reporte de caso utilizamos la técnica de construcción tridimensional de los senos frontales a través de la generación de figuras sólidas representativas de la morfología sinusal. Tras el análisis comparativo de la tomografía antemortem y postmortem de la presunta víctima, pudimos establecer similitudes tanto en las variaciones de tamaño, forma, simetría y contorno de márgenes, como en la presencia y número de septos, lo que nos permite inferir que las dos imágenes descritas pertenecen al mismo individuo, estableciéndose así la identidad del cadáver encontrado.

18.
J. oral res. (Impresa) ; 11(1): 1-8, may. 11, 2022. tab
Artigo em Inglês | LILACS | ID: biblio-1399824

RESUMO

Introduction: The aim of this study was to assess the agreement between oral and maxillofacial radiologists (OMFR) and oral and maxillofacial surgeons (OMFS) for the detection of bifid mandibular canal (BMC) and accessory mental foramen (AMF) using cone-beam computed tomography (CBCT). Material and Methods: This retrospective study involved 22 examiners (11 OMFR and 11 OMFS) who independently assessed 30 CBCT volumes from patients (n = 60 hemi-mandibles) under preoperative radiographic evaluation for implant placement. The examiners scored the presence of BMC and AMF in each hemimandible. The interexaminer agreements were assessed using Fleiss' kappa statistics. Results: For intra-examiner agreement, 40% of the sample was reevaluated. The interexaminer agreement between OMFR and OMFS was slight (0.12) for the detection of BMC and fair (0.24) for AMF. The agreement among OMFR for detection of BMC was fair (0.22), and it was slight among OMFS (0.15). The agreement among OMFR for detection of AMF was substantial (0.61), and among OMFS it was fair (0.22). Agreements between OMFR and OMFS were slight for BMC and fair for AMF, independently of the years of experience. Intraexaminer agreement ranged from 60% to 90% among OMFR and from 55% to 90% among OMFS. Conclusion: A slight and a fair agreement between OMFR and OMFS was found for the detection of BMC and AMF, respectively. In general, OMFR obtained higher agreement among themselves, mainly for detection of AMF.


Introducción: El objetivo de este estudio fue evaluar la con-cordancia entre los radiólogos orales y maxilofaciales (ROMF) y los cirujanos orales y maxilofaciales (COMF) para la detección del canal mandibular bífido (CMB) y el foramen mentoniano accesorio (FMA) mediante tomografía computarizada de haz cónico. CBCT). Material y Métodos: Este estudio retrospectivo involucró a 22 examinadores (11 ROMF y 11 COMF) que evaluaron de forma independiente 30 volúmenes CBCT de pacientes (n = 60 hemimandíbulas) bajo evaluación radiográfica preoperatoria para la colocación de implantes. Los examinadores puntu-aron la presencia de CMB y FMA en cada hemimandíbula. Los acuerdos entre examinadores se evaluaron utilizando las estadísticas kappa de Fleiss. Resultados: Por concordancia intraexaminador se reeva-luó el 40% de la muestra. El acuerdo entre examinadores entre ROMF y COMF fue ligero (0,12) para la detección de CMB y regular (0,24) para FMA. La concordancia entre ROMF para la detección de CMB fue regular (0,22) y leve entre COMF (0,15). El acuerdo entre ROMF para la detección de FMA fue sustancial (0,61), y entre COMF fue justo (0,22). Los acuerdos entre ROMF y COMF fueron leves para CMB y justos para FMA, independientemente de los años de experiencia. La concordancia entre examinadores varió del 60 % al 90 % entre ROMF y del 55 % al 90 % entre COMF. Conclusión: Se encontró un acuerdo leve y justo entre ROMF y COMF para la detección de CMB y FMA, respec-tivamente. En general, se obtuvo mayor acuerdo entre ROMF, principalmente para la detección de FMA.


Assuntos
Humanos , Masculino , Feminino , Cirurgiões Bucomaxilofaciais , Radiologistas , Forame Mentual/diagnóstico por imagem , Canal Mandibular/diagnóstico por imagem , Brasil , Reprodutibilidade dos Testes , Estudos Retrospectivos , Tomografia Computadorizada de Feixe Cônico , Variação Anatômica , Mandíbula/diagnóstico por imagem
19.
Dentomaxillofac Radiol ; 51(4): 20210404, 2022 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-34860568

RESUMO

OBJECTIVES: To assess the dynamic range and enhancement ability of radiographs acquired with contemporary digital systems. METHODS: Five repeated periapical radiographs of human mandibles with an aluminium step-wedge were acquired using two sensor-based and three photostimulable phosphor plate-based systems and an X-ray unit at ten exposure times 0.020, 0.032, 0.063, 0.080, 0.100, 0.200, 0.320, 0.400, 0.500, and 0.630 s. All images had their brightness and contrast enhanced by two experienced oral and maxillofacial radiologists in consensus and were exported as both the original and enhanced file formats. Mean grey values were obtained from the aluminium steps and tabulated with their corresponding thicknesses for each exposure time, digital radiographic system, and file format. Images with saturated steps were excluded and the mean grey values from the remaining images were averaged to assess image brightness and the angular coefficient of the linear trendlines was generated from the relationship between mean grey values and their corresponding aluminium thicknesses to assess image contrast. Brightness and contrast values were compared using two-way ANOVA with post-hoc Tukey (α = 0.05). RESULTS: Photostimulable phosphor plate-based digital radiographic systems had a broader dynamic range. Longer exposure times produced original images with lower brightness and variable contrast (p < 0.05). Subjective enhancement significantly increased or reduced brightness and/or contrast in some systems (p < 0.05). CONCLUSIONS: Contemporary digital radiographic systems present different dynamic ranges and exposure-related brightness and contrast. Image enhancement may be a valuable tool at slightly suboptimal exposure times.


Assuntos
Alumínio , Radiografia Dentária Digital , Humanos , Mandíbula , Intensificação de Imagem Radiográfica/métodos , Radiografia Dentária Digital/métodos
20.
Clin Oral Investig ; 26(1): 1025-1033, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34324084

RESUMO

OBJECTIVE: To compare the expression of the volumetric alteration (VA) artifact between cylindrical and convex triangular fields of view (FOVs) using high-density materials in different positions in two cone-beam computed tomography (CBCT) devices. MATERIALS AND METHODS: Cylinders of five high-density materials (amalgam, chromium-cobalt, gutta-percha, titanium, and zirconium) with known physical volume were individually submitted to CBCT acquisition in four positions inside a polymethylmethacrylate phantom using two different FOV shapes (convex triangular and cylindrical) on the Veraviewepocs® R100 (R100) and Veraview® X800 (X800) devices. Two oral radiologists obtained the tomographic volumes by segmenting each cylinder. The difference between the tomographic and physical volumes corresponded to the VA. These values were analyzed by intraclass correlation coefficient and analysis of variance for repeated measures with Tukey post hoc test (α = 5%). RESULTS: The FOV influenced the VA only in the X800 device (p = 0.014): the VA in the triangular FOV was greater than in the cylindrical FOV. The VA in the triangular FOV of the X800 device was greater than the R100 device (p < 0.0001). The material influenced the expression of the VA only in the R100 device (p < 0.0001); gutta-percha presented the highest VA, being underestimated, and differing from the other materials (p < 0.01). CONCLUSION: The triangular FOV increased the VA of high-density materials in the X800 device. CLINICAL RELEVANCE: It is important to know if there is an influence on the volumetric alteration artifact of dental materials due to the different image formation geometry in the convex triangular FOV.


Assuntos
Artefatos , Tomografia Computadorizada de Feixe Cônico , Amálgama Dentário , Guta-Percha , Imagens de Fantasmas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...